CNPS-ML-B11 Mud Density Sensor

CNPS-ML-B11 Mud Density Sensor

WORKING PRINCIPLE

The CNPS-ML-B11 drilling fluid density sensor uses a differential pressure differential mode of operation. Two pressure bellows with corrugated membranes installed at different heights detect the pressure difference produced by the liquid at different depths. The pressure difference is proportional to the liquid density. The two “H” shaped vibration beams on the sensor convert the differential pressure signal into a frequency signal, send it to the pulse counter, and then pass the difference between the two frequencies directly to the CPU (microprocessor) for data processing. After D/A conversion, Output 4 to 20mA standard DC current signal corresponding to drilling fluid density can also be directly transmitted by digital signal. EJA118W transmitter can also transmit data through digital communication mode through I/O port and external device BT200. That is to use HART protocol (1.2kHz) to superimpose data signal on 4~20mA signal line. When data communication, frequency signal No interference effect on the 4-20mA signal.

2 Technical indicators Power supply:+17V ~ 42V DC(Recommend +24V DC)

Measuring range:0.96 ~ 2.76g/cm3(Can be set according to user needs)

Output current:4~20mA DC

Measurement accuracy: ±0.5%FS

Environmental conditions:Sensor working temperature -40℃ ~ +85℃

Relative humidity:5 ~ 95%RH 3

Operation 3.1 Sensor installation The distance between the two pressure diaphragm of the CNPS-ML-B11 drilling fluid density sensor is 45cm and 60cm, the outlet density sensor is 45cm, and the entrance density sensor is 60cm。 According to the needs of measurement, we choose to install sensors on the drilling fluid inlet and drilling fluid outlet respectively. When drilling fluid level fluctuates, the upper and lower flanges must be immersed in the mud to keep it upright and not tilted, otherwise it will affect the accuracy of measurement. The transmitter changer shall be above the mud level and not immersed in mud.。 3.2 Sensor connection Open the seal box cover sensor terminal,”+” SUPPLY +24V “-” power supply terminal connected to the signal shown in Figure 1.     Transmitter terminal   Earthing end Earthing end Figure 1 Wiring diagram of density sensor 4  Sensor adjustment The CNPS-ML-B11 type drilling fluid density sensor has been adjusted at the time of leaving the factory, and generally needs no on-site adjustment. If the sensor is in trouble, it must be adjusted on-site. The special calibrating instrument BT200 must be used. The adjustment method is as follows:

(1)Remove the protective cover of the lower end of the sensor, install the special pressure flange plate on the sensor diaphragm at the bottom of the sensor, and connect the outlet of the pressure detector and the pressure flange inlet to ensure that the seal is not leaking.

(2)Press the diagram to connect sensors, digital multimeter, DC power supply and calibrating instrument BT200 together, as shown in Figure 2. Figure 2  Density sensor adjustment connection diagram

(3)The measuring range of CNPS-ML-B11 type density sensor is set to 0.96 to 2.76g/cm3 when the factory is released. When the sensor is placed in the air, the output current is 3.20mA.。 According to the data given in Table 1, the output pressure of the pressure detector is adjusted and the output current value corresponding to the pressure difference is observed. If the output value deviates from the larger, the BT200 calibrator should be used to adjust the zero. Table 1  Liquid density — the corresponding relation between pressure difference and output current of two pressure diaphragm. Two pressure diaphragm’s spacing 45cm(Export density) Density(g/cm3 ) 0.96 1.32 1.68 2.04 2.40 2.76 Pressure difference(kPa) 4.32 5.94 7.56 9.18 10.80 12.42 Output current(mA) 4.00 7.20 10.40 13.60 16.80 20.00 Two pressure diaphragm’s spacing is 60cm(Entrance density) Density(g/cm3 ) 0.96 1.32 1.68 2.04 2.40 2.76 Pressure difference(kPa) 5.76 7.92 10.08 12.24 14.40 16.56 Output current(mA) 4.00 7.20 10.40 13.60 16.80 20.00   5 Sensor testing If you want to use a simple way to test the sensor linearity, you can use the check flange, as shown in Figure 3. Remove the sensor shield and install the check flange on the sensor’s lower end induction diaphragm. In the plastic hose in the water, first check the flanges of the deflation screw loosened, to add a certain amount of water to make the gas screw water overflow, and then screw tightened, gently tapping plastic hose, the tube wall of bubbles out. Then the power supply is attached and the ammeter is put into the output circuit to change the height of the liquid surface in the plastic hose. It can be seen that the output signal is changed. This change should be roughly in accordance with table

2. Table 2 The relationship between the density of liquid and the height of water column and the output current. Two pressure diaphragm’s spacing 45cm(Export density) Density(g/cm3) 0.96 1.32 1.68 2.04 2.40 2.76 The height of water(mm) 430 600 750 920 1080 1240 Output current(mA) 4.00 7.20 10.40 13.60 16.80 20.00 Two pressure diaphragm’s spacing is 60cm(Entrance density) Density(g/cm3) 0.96 1.32 1.68 2.04 2.40 2.76 The height of water(mm) 580 790 1010 1220 1440 1650 Output current(mA) 4.00 7.20 10.40 13.60 16.80 20.00

3 Sensor test connection diagram 6 Maintenance

(1)The transmitter part must be sealed to prevent water damage.

(2)The sensor is designed to withstand shock and vibration, but it should be installed in places with less impact and less vibration.

(3)The two flanges of the sensor should be flushed regularly. If the cleaning is not in time, the sludge will be blocked and the flange will affect the measurement results. It is forbidden to clean mud with screwdrivers and other sharp appliances, so as not to damage the flange diaphragm, and affect the measurement results.

(4)When the sensor is not used, the residual liquid in the flanges of the flanges should be thoroughly cleaned.

Weight 45 kg